Switch Intended for Self Ballasted Lamp (SBL) Load


Sensors India has developed an SBL Load as per IS: 3854 – 2023, covering of the standard prescribed by BIS & IEC standard
IPeak and Ft Values for Different Distribution Systems
Rated Power (W) | IPeak (A) – 220/380V | IPeak (A) – 230/400V | IPeak (A) – 240/415V | Ft (A²s) – 220/380V | Ft (A²s) – 230/400V | Ft (A²s) – 240/415V |
Up to 10 | 108 | 162 | 100 | 2.8 | 5.9 | 60 |
10 – 13 | 142 | 162 | 150 | 5.5 | 5.9 | 60 |
13 – 16 | 170 | 200 | 200 | 9 | 11.5 | 100 |
16 – 20 | 192 | 231 | 250 | 13 | 18.5 | 150 |
Modes of Operation
- Measurement Mode
- Provides Output Voltage and Output Current terminals for measurement via an oscilloscope.
- Switch under test remains in ON position.
- Load is switched on at 900 ± 5 phase-angle with necessary control provisions.
- Digital oscilloscope measures and displays Ipeak.
- I²t is calculated and displayed via software.
- Normal Operation Mode
- Provides suitable terminals for measuring Output Voltage and Output Current.
- SBL Load Adjustments: Resistance (R2) and capacitance (C) adjustments allow tuning to achieve desired Ipeak and I²t values.