sensorsindia.com

Switch Intended for Self Ballasted Lamp (SBL) Load

Sensors India has developed an SBL Load as per IS: 3854 – 2023, covering of the standard prescribed by BIS & IEC standard

IPeak and Ft Values for Different Distribution Systems

Rated Power (W)

IPeak (A) – 220/380V

IPeak (A) – 230/400V

IPeak (A) – 240/415V

Ft (A²s) – 220/380V

Ft (A²s) – 230/400V

Ft (A²s) – 240/415V

Up to 10

108

162

100

2.8

5.9

60

10 – 13

142

162

150

5.5

5.9

60

13 – 16

170

200

200

9

11.5

100

16 – 20

192

231

250

13

18.5

150

Modes of Operation

  1. Measurement Mode
  • Provides Output Voltage and Output Current terminals for measurement via an oscilloscope.
  • Switch under test remains in ON position.
  • Load is switched on at 900 ± 5 phase-angle with necessary control provisions.
  • Digital oscilloscope measures and displays Ipeak.
  • I²t is calculated and displayed via software.
  1. Normal Operation Mode
  • Provides suitable terminals for measuring Output Voltage and Output Current.
  • SBL Load Adjustments: Resistance (R2) and capacitance (C) adjustments allow tuning to achieve desired Ipeak and I²t values.