ENDURANCE TEST
Making-Breaking and Normal Operation Test for Plug and Socket Outlets
((IS-1293-2019)


Total Voltage and current range of the source: 200-270 V, 6-25 A AC
(Depending upon the socket ratings selected) Load Current options: 6, 10, 13, 15 16, 20, 25 Amp for Normal Operation
Making-Breaking 1.25 times 6, 10, 13, 15 16, 20, 25, 32 Amp for Rated Voltage Options: 220 V, 230 V, 240 V and 250 V
(As per user specifications)
Rated Voltage Options: 220 V, 230 V, 240 V and 250 V 50 / 60 Hz operation as per incoming line frequency (As per user specifications)
Power Factor: 0.3 for Breaking Capacity and 0.6 for Normal Operation auto settable
Technical Parameters
- Air Source: 4~6kg/cm²
- Control Method: PLC program control/touchscreen display settings
- Connection Time: Adjustable from 0 to 99.9 seconds (minutes)
- Cycle Time: Adjustable from 0 to 99.9 seconds (minutes)
- Counter: Pre-settable from 0 to 999,999 cycles
- Workstations: 3 units
- Sample Clamping: Adjustable up and down
- Power Supply: AC220V/50Hz/