sensorsindia.com

ENDURANCE TEST
Making-Breaking and Normal Operation Test for Plug and Socket Outlets

((IS-1293-2019)

Total Voltage and current range of the source: 200-270 V, 6-25 A AC

(Depending upon the socket ratings selected) Load Current options: 6, 10, 13, 15 16, 20, 25 Amp for Normal Operation

 Making-Breaking 1.25 times 6, 10, 13, 15 16, 20, 25, 32 Amp for  Rated Voltage Options: 220 V, 230 V, 240 V and 250 V 

(As per user specifications)

Rated Voltage Options: 220 V, 230 V, 240 V and 250 V  50 / 60 Hz operation as per incoming line frequency (As per user specifications)

Power Factor: 0.3 for Breaking Capacity and 0.6 for Normal Operation auto settable

Technical Parameters

  • Air Source: 4~6kg/cm²
  • Control Method: PLC program control/touchscreen display settings
  • Connection Time: Adjustable from 0 to 99.9 seconds (minutes)
  • Cycle Time: Adjustable from 0 to 99.9 seconds (minutes)
  • Counter: Pre-settable from 0 to 999,999 cycles
  • Workstations: 3 units
  • Sample Clamping: Adjustable up and down
  • Power Supply: AC220V/50Hz/