Switch Intended for Self Ballasted Lamp (Load)
Switch Intended for Self Ballasted Lamp (SBL) Load as per IS: 3854 – 2023 Clause 19.3. Sensors India has developed SBL Load as per the standard required by BIS. It covers table 22 of IS: 3854.
Table 22 Values for IPeak and Ft Depending on the type of Distribution System (Clause 19.3)
Rated Current ‘A’
|
Distribution system ‘V’
220/380
230/400
240/415
IPeak
(A)
|
Distribution system ‘V’
220/380
230/400
240/415
Ft
(A2s)
|
Distribution system ‘V’
220/380
230/400
240/415
IPeak
(A)
|
Distribution system ‘V’
220/380
230/400
240/415
Ft
(A2s)
|
Distribution system ‘V’
220/380
230/400
240/415
Rated Power of the SBL circuit
(W)
|
Distribution system ‘V’
220/380
230/400
240/415
Rated Power of the SBL circuit
(W)
|
Up to and including 10
|
108
|
2.8
|
162
|
5.9
|
100
|
60
|
Above 10 up to and including 13
|
142
|
5.5
|
162
|
5.9
|
150
|
60
|
Above 13 up to and including 16
|
170
|
9
|
200
|
11.5
|
200
|
100
|
Above 16 up to and including 20
|
192
|
13
|
231
|
18.5
|
250
|
150
|
4) Modes of Operation: Measurement Mode and Normal Operation modes will be provided as follows.
Measurement Mode:
- In Measurement mode, for Output Voltage and Output Current terminals will be provided to measure the same by using an Oscilloscope.
- For this mode, Switch, under test will be kept in ON position.
- In this mode, Load would be Switched on at 900 ± 5 phase-angle. To achieve this necessary controls will be provided.
- Digital Oscilloscope will be provided to measure and display Ipeak
- Provisions to adjust/select suitable time.
- I2t will be calculated (by necessary means/software) and displayed.
Normal Operation Mode:
- Measurement Terminals: For the measurement of Output Voltage and Output Current Suitable Oscilloscope terminals will be provided.
II. SBL Load Adjustments: For the adjustment of Output Current and Time to get the
desired valves of Ipeak and I2t, adjustments for R2 and C will be provided.
Consists
- 3 Nos. of Voltmeter, Wattmeter, Current meter for 3 samples.
- Variable transformer to adjust the voltage as desired.
- The resistance & capacitance Bank as per the standard to test 3 samples of type each of 4 Rating.
The entire Load Bank is housed in aluminium extruded section and powder coated DA Grey colour.
The system is also built-in to ensure peak current as per table 22 column No. 1.
It can be verified on oscilloscope (Not part of Load Bank).
|